Leaking Fort Collins Water Heater Pressure Relief Valve

Posted by on Dec 9, 2014 in Gas Water Heater Repair Fort Collins, Water Heater Repair Fort Collins

The pressure relief valve of a water heater has an essential job – making certain the water heater tank does not explode. So with that in mind, Water Heater Repair Fort Collins wants to ensure homeowners know ways to best take care of it. They will leak when the valve wears out or when the water storage tank pressure gets higher then the relief point.Hot Water Heater Repair Fort Collins

We recommend that a minimum of twice a year, house owners test to ensure the pressure relief valve, or T&P valve as we will call it, is working properly. All one has to do is raise the deal with for a couple of seconds and release it. It should snap back to its original position. When it is lifted, one could hear the noise of pressure being released , much like the noise of air coming out of a tire pump when being disconnected. Likewise, a little water may come out as well. Both are regular. If the valve has not been tested in a long time, it may stick at first as well.

However, if the handle doesn’t snap back, or if it remains to leak a little water, that is not typical. If it still leakages some, raise the handle a few more times to see if it does re-seat itself. You might wish to wait a day or so it see if it re-seats itself before assuming it needs to be replaced.

Hot Water Heater Repair Fort Collins would choose to handle any T&P valve replacements for you, so though hot water heaters are usually relatively maintenance free, there are some safety preventative measures one need to bear in mind. With that in mind here is a summary of a pressure relief valve replacement.

1. The gas to the water heater needs to be turned off, or the breaker for an electric water heater.
2. The cold water cut-off valve has to be closed .
3. The valve below the T&P valve needs to be opened to drain a little water in order to relieve some of the pressure in the storage tank.
4. The overflow pipe of the T&P valve needs to be taken off. It might have to be cut off if it is soldered or firmly glued.
5. The pressure relief valve has to be unscrewed with a pipe wrench.
6. Wrap the new T&P valve with Teflon tape and screw it in place. Make sure the overflow pipe opening is placed away from the storage tank.
7. Reattach the drain pipe, likewise using brand-new Teflon tape.
8. Turn the water back on, and examine your work for any leakages.